Differential Scanning Calorimeter (DSC) Suppliers in UAE

Differential Scanning Calorimeter (DSC)

The DSC 600 differential scanning calorimeter provides accurate heat flow data for your materials and samples- be they polymers, pharmaceuticals, or petroleum products. The instrument compares your sample to a reference crucible under similar thermal conditions. Hence, you obtain detailed information on melting, crystallization, and the reaction process without any ambiguity.

Warranty

Installation

Training

Product overview

The DSC 600 differential scanning calorimeter provides accurate heat flow data for your materials and samples- be they polymers, pharmaceuticals, or petroleum products

A differential scanning calorimetry instrument works by holding a sample and an empty reference crucible at the same temperature throughout a test run. Any heat absorbed or released by the sample shows up as a difference between the two, plotted as heat flow against temperature. Peaks in that plot point to real physical or chemical events happening inside the material, melting, crystallizing, curing or decomposing.

This is the core strength of DSC differential scanning calorimetry as a technique. It doesn’t just tell you that something changed, it shows you exactly where on the temperature scale the change happened and how much energy was involved.

The DSC 600 uses a mineral furnace built to be as light as possible. Less mass around the sample chamber means less heat gets absorbed by the furnace itself, so temperature stays uniform and the instrument responds faster to changes. Labs running back to back samples benefit from shorter equilibration between tests.

Cooling Setup

Three cooling paths are available with this dsc calorimeter, water, mechanical refrigeration or liquid nitrogen. Water cooling suits routine work near ambient conditions. Mechanical cooling extends the lower range without needing consumables. LN2 cooling pushes furthest into sub zero territory for labs working with materials that need deep cold analysis.

 

  • Runs on water, mechanical or LN2 cooling, chosen based on what your samples actually need rather than a fixed setup
  • Mineral furnace keeps heat loss low and temperature even across the chamber
  • Optional high pressure configuration handles measurements up to 1000 psi
  • Operates in the polymer, pharmaceutical, and petrochemical testing sectors without the requirement of different devices.
  • Adjustable cooling systems: water, mechanical, or liquid nitrogen (LN2).
  • Lightweight mineral furnace construction minimizes heat loss and ensures better heat uniformity.
  • Optional high-pressure DSC unit allows working at pressure levels of up to 1000 psi.

The DSC 600 model of differential scanning calorimeter (DSC) is used to perform accurate heat-flow tests of polymers, pharmaceuticals, and petrochemicals.

Specification Option 1 Option 2 Option 3
Temperature Range -150~600°C
Temperature Accuracy ±0.1°C
Temperature Precision ±0.01°C
Program Rate 0.1~200°C/min
Cooling Mode Water Cooling Refrigerated Cooling Liquid Nitrogen Cooling
Maximum Temperature 600°C 450°C 600°C
Minimum Temperature Ambient Temperature -40°C or -90°C -150°C
Calorimetric Accuracy ±0.1%
Noise 0.5 μW
Gas Nitrogen, Argon, Helium, Compressed Air, Oxygen, etc.
Sampling Frequency 10 Hz
Weight 27 lbs.
Dimensions 17 in (W) × 17 in (D) × 9.5 in (H)
Options
Gas Controller 4 Channel Automatic Gas Switching
Software Functions Specific Heat Capacity