Home / Products / Testing & Measurement / Petroleum Physical Property Solutions / Particle contamination in aviation fuel Av Count3 Particle Counter
Particle contamination in aviation fuel Av Count3 Particle Counter

Particle contamination in aviation fuel Av Count3 Particle Counter

The AvCount3 is a compact particle counter built to detect aviation fuel contamination with speed and precision. It measures particle and water droplet levels in fuels, kerosene, and hydraulic oils, giving labs a reliable way to run particulate contamination analysis without heavy operator training.

Warranty

Installation

Training

Product overview

The AvCount3 is a compact particle counter built to detect aviation fuel contamination with speed and precision.

Keeping aviation fuel clean isn’t optional, and catching contamination early makes a real difference downstream. The AvCount3 was built with that in mind. It’s a compact, bench top automatic particle counter that measures the size and spread of particles and water droplets across a range of fluids, including aviation fuel, kerosene, biodiesel, low viscosity oils, and hydraulic oils. When it comes to particulate contamination in aviation fuels specifically, this unit is built to catch what matters and flag it clearly.

What stands out is how little training it actually takes to run. The touch screen interface keeps things simple, and since the whole test process is automated, operators aren’t stuck babysitting the machine through every step. That frees people up to handle other tasks while the instrument does its job, which ends up saving on labor time in busier labs.

For samples with higher viscosity, the AvCount3 runs a built in dilution protocol so results stay accurate even outside standard fluid ranges. You also get a real time view of test progress on screen, so there’s no waiting around wondering how far along a run is. As an aviation fuel particulate contaminant analyzer, it fits well into labs that need dependable, repeatable results without a steep learning curve.

Standard What It Covers
DEF STAN 91-091 Aviation fuel specification
ASTM D975 Specification for diesel fuel oils, including biodiesel, biodiesel blends, and petroleum products
IP 565 Cleanliness level determination for aviation turbine fuels using a portable automatic particle counter
ASTM D7619 Counting and sizing particles in light and middle distillate fuels and liquid biofuels
GOST 17216 Grading liquid purity levels
NAS 1638 Cleanliness requirements for parts used in hydraulic systems
DEF STAN 91-86 Turbine fuel specification for high flash type aviation kerosene
ASTM D7647 Automatic particle counting for lubricating and hydraulic fluids using dilution to eliminate water and soft particle interference
ISO 60970 Counting and sizing particles in insulating liquids
ISO 4406 Coding contamination levels of solid particles in hydraulic fluids
ASTM D6786 Particle count method for mineral insulating oil using automatic optical particle counters
ASTM D7467 Specification for diesel fuel oil and biodiesel blends B6 to B20
JIS B 9932:2012 Calibration method for automatic particle counters in hydraulic pressure liquid
JIS B 9933:2021 Contamination degree code display for hydraulic solid particles
JIS B 9934:2012 Cleanliness measurement using automatic particle counting with light shielding principle
IP 630 Concentration of dispersed particles in diesel fuel using light obscuration method
IP 646 Concentration of dispersed particles in marine methanol fuel using light obscuration method
  • ·         ISO 11171 calibration
  • ·         Cumulative counts/ml
  • ·         ISO 4406 cleanliness codes
  • ·         Colour touch screen
  • ·         Dilution ratio calculation
  • ·         Real time display of test progress
  • ·         User programmable
  • ·         LIMS, network and VNC connectivity
  • ·         Programmable alarm limits
  • ·         14 embedded test methods
  • ·         In-field verification and calibration
Item Detail
Particle size range ISO 11171, 4 µm(c) to 70 µm(c), larger size calibration available on request
Measuring channels 16 size channels displayed, covering 4 µm(c) to 70 µm(c) and 2 µm(c) to 100 µm(c) per ISO 4402
Max counts per measurement 60,000 per ml
Max sample viscosity 64 mm2/s using internal pump, up to 200 mm2/s pressure fed at 3 BarG with SA1950-0 accessory
Sample temperature range Ambient, 0°C to 70°C
Results 500,000 result memory, with printing via internal printer or export to LIMS, USB, or QR code
Sample flow rate 30 ml per minute, ±5 ml
Total sample volume 80 ml for ASTM D7619 and IP 565, from 20 ml for other methods, includes flush cycles
Power 100 to 240V, 50 or 60 Hz, auto sensing universal power supply
Size (H x W x D) 37 cm x 23 cm x 27 cm
Weight 6 kg
CCCN code Tariff 90278990

This particle counter supports contamination testing across

  • Petrochemical 
  • Research & Developments
  • Refineries
  • Independent testing laboratories
  • Lubricant analysis

Find the Right Solution for Your Laboratory