MiniLab BOD Series (BOD Analyzer) Suppliers in UAE

MiniLab BOD Series (BOD Analyzer)

SEAL Analytical’s MiniLab BOD series is a lab robotics systems solution that automates every step of biochemical oxygen demand (BOD) pretreatment and analysis. This Robotics system replicates manual methods with speed and consistency, handling pH adjustment, chemical and seed additions, and dilutions, so operators simply load samples and walk away.

Warranty

Installation

Training

Product overview

SEAL Analytical’s MiniLab BOD series is a lab robotics systems solution that automates every step of biochemical oxygen demand (BOD) pretreatment and analysis.

SEAL Analytical’s MiniLab BOD series is a robotics system that automates every aspect of biochemical oxygen demand (BOD) pre-treatment and analysis through streamlined software configuration and minimal user interaction. As one of the more capable laboratory robots on the market, precision robotics replicate traditional manual methods with speed, accuracy and consistency, handling preparation steps such as pH adjustment, chemical and seed additions, and dilutions. Operators simply add the samples and let the MiniLab take care of the rest.

This Lab Robotics Systems platform supports 24/7 continuous operation, from barcode scanning and pH reading and adjustment through capping, dosing, and dissolved oxygen reading, while fully audited sample management keeps results precise, repeatable, and compliant with regulatory standards. High analytical capacity—from 15 to 300 samples per system, depending on application and model—free staff from repetitive manual tasks. BDH supplies the MiniLab BOD series to laboratories across the United Arab Emirates (UAE), Oman, Qatar, Kuwait, Bahrain, and Saudi Arabia as a specialist supplier.

Standard Method 5210 B, ASTM D888, EPA 405.1, ISO 1899-1, ISO 1899-2, and ISO 5815-1

Automation

  •     Seamless sample additions for 24/7 continuous operation and analysis
  •     Sample preparation, including barcode scanning, conductivity, pH reading and adjustment, homogenisation, air purging and pre-dilutions
  •     BOD analysis including capping/decapping, sample dosing, addition of dilution water, ATU and seed, and DO reading

Compliance

  •     Precise, repeatable results free of human error
  •     Fully audited sample management for total compliance with regulatory standards
  •     Exportable results
  •     Uses standard BOD bottles
  •     Optional temperature-controlled enclosure

Efficiency

  •     High throughput with multi-probe, multi-dispense options
  •     Improved repeatability and reproducibility
  •     Reduced lab process cycle times
  •     High analytical capacity: 15 to 300 samples per system, depending on application and model
  •     Frees staff from repetitive, time-consuming manual tasks

The BOD test is used to estimate the oxygen depletion in water samples within the practical range of 0.5 to 20.0 mg/L ± 0.1 mg/L, and this is equal to Standard Methods 5210 B, ASTM D888, EPA 405.1, ISO 1899-1, ISO 1899-2, and ISO 5815-1. Biochemical Oxygen Demand (BOD) tests the oxygen consumption in five days: the sample is taken on day zero, and this is for the initial DO measurement, while the final measurement is done on day five.